Temperature Range:
Moving inside the drag chain: +5°C to 80°C
Moving outside the drag chain: -5°C to 80°C
Bending Radius:
Moving inside the drag chain: Minimum 15 xd
Moving outside the drag chain: Minimum 12 xd
Drag Chain Life:
Factors affecting the service life of cables within the drag chain:
Temperature, Bending radius, Travel distance, Speed
TUV and Stable Drag Chain Testing Standards:
Temperature range: +15°C to 25°C
Bending radius: 15xd
Travel distance: 0.9 meters
Speed: 90 cycles/minute
The drag chain’s life can reach: 10 million cycle times
Standard Voltage: 600/1000V
Test Voltage: 4000V
Application
Especially suitable for mechanical equipment, machine tools, and other applications involving continuous high-intensity and high-speed bending of drag chains.
Suitable for use in short-distance, high-speed drag chains.
The TY1008 series drag chain cables have been widely applied in indoor drag chain systems for warehousing equipment, processing equipment, packaging equipment, indoor cranes, glass equipment, as well as in the packaging and logistics industries
Cable Structure
Product Structure:
Complies with UL758 STYLE 2570
Conductor:
Fine bare copper stranded wire with high bend strength, conforming to DIN VDE 0295 Class 5 and IEC 60228 Class 5
Insulation:
High mechanical performance TPE polymer insulation
Conductor Colors:
For a single conductor, it uses one yellow-green ground wire along with black conductors marked with white numbers.
For two conductors, the power line uses one yellow-green ground wire with black conductors marked with white numbers; the brake line uses both black and white colors.
Phase Shielding:
High-strength tin-plated copper wire shielding with optical coverage > 85%.
Twisting Method:
Optimal pitch twisting.
Overall Shielding:
High-strength tin-plated copper wire shielding with optical coverage > 85%.
Outer Jacket:
Modified high-strength PVC polymer.
| Item | Product Code | Number of Cores and Cross-Sectional Area | Approximate Outer Diameter | Color | Product Number | MOQ |
| 1 | TY1008.02.0075 | 2×0.75 | 6.30 | orange | C-2200 | |
| 2 | TY1008.04.0050 | 4G0.5 | 6.60 | orange | C-2201 | |
| 3 | TY1008.04.0075 | 4G0.75 | 7.20 | orange | C-2202 | |
| 4 | TY1008.04.0100 | 4G1.0 | 7.80 | orange | C-2203 | |
| 5 | TY1008.04.0150 | 4G1.5 | 8.50 | orange | C-2204 | |
| 6 | TY1008.04.0250 | 4G2.5 | 10.00 | orange | C-2205 | ※ |
| 7 | TY1008.04.0400 | 4G4.0 | 11.50 | orange | C-2206 | ※ |
| 8 | TY1008.04.0600 | 4G6.0 | 13.50 | orange | C-2207 | ※ |
| 9 | TY1008.04.1000 | 4G10.0 | 18.00 | orange | C-2208 | ※ |
| 10 | TY1008.04.1600 | 4G16.0 | 22.00 | orange | C-2209 | ※ |
| 11 | TY1008.04.2500 | 4G25.0 | 26.20 | orange | C-2210 | ※ |
| 12 | TY1008.04.3500 | 4G35.0 | 30.00 | orange | C-2211 | ※ |
| 13 | TY1008.06.1920 | 4G0.75+(2×0.5+B) | 8.70 | orange | C-2212 | |
| 14 | TY1008.06.1719 | 4G1.0+(2×0.75+B) | 9.80 | orange | C-2214 | |
| 15 | TY1008.06.1519 | 4G1.5+(2×0.75+B) | 10.40 | orange | C-2215 | ※ |
| 16 | TY1008.06.1319 | 4G2.5+(2×0.75+B) | 11.80 | orange | C-2217 | ※ |
| 17 | TY1008.06.1315 | 4G2.5+(2×1.5+B) | 12.50 | orange | C-2219 | ※ |
| 18 | TY1008.06.1115 | 4G4.0+(2×1.5+B) | 14.40 | orange | C-2221 | ※ |
| 19 | TY1008.06.0915 | 4G6.0+(2×1.5+B) | 16.30 | orange | C-2223 | ※ |
| 20 | TY1008.06.0715 | 4G10.0+(2×1.5+B) | 19.60 | orange | C-2225 | ※ |
| 21 | TY1008.06.0515 | 4G16.0+(2×1.5+B) | 23.60 | orange | C-2227 | ※ |
| 22 | TY1008.06.0315 | 4G25.0+(2×1.5+B) | 28.00 | orange | C-2228 | ※ |
| 23 | TY1008.06.0215 | 4G35.0+(2×1.5+B) | 31.50 | orange | C-2229 | ※ |
Notes
1: G = with yellow-green ground wire; X = without yellow-green ground wire
2: American standard AWG sizes are approximate; actual cross-sectional area prevails
3: Minimum order for specifications with ※ is 10 meters, shipped as needed
.