Technical Parameter Ultra Flexible Cable Power Customized Flex Cables
Temperature
Mobile installation -5 ° C to+80 ° C
Fixed installation -15 ° C to+105 ° C
· Named voltage UO/U 300/500 V
· Test voltage 2000V
Insulation resistance:
Minimum 20 mohm x km
The minimum boast radius:
Mobile installation 6X cable diameter
Fixed installation 4X cable diameter
Comply with EU ROHS, Reach regulations requirements
Structure Ultra Flexible Cable Power Customized Flex Cables
Bare copper conductor, ultra -fine copper wire
Condensing DIN VDE0295 Category 6 and IEC 60228 Category 6
Special PVC insulation
Color core wire logo
The line core uses the best section distance to lay layered twisted
Put a yellow -green ground line [3 cores and above]
Special PVC outer condom
Black [Ral2003] matte
Ultra Flexible Cable Power Customized Flex Cables Parameter | ||||
No. | Product Code | Cores Number and cross-sectional area | Approximate outer diameter (mm) | Outer sheath color |
(NO.Xm㎡) | ||||
1 | MC-YY3007.04.0050 | 4Gx0.5 | 6.3 | Black |
2 | MC-YY3007.06,2024 | 4Gx0.5+2×0.2 | 6.3 | Black |
3 | MC-YY3007.04.0075 | 4Gx0.75 | 6.3 | Black |
One-stop procurement service provider: