YP506 3X2X0.2mm²(24AWG) PUR drag chain conveyors polyurethane cable twisted pair
drag chain conveyors polyurethane cable is a widely used cable type in many industrial and commercial applications.
This cable is popular mainly due to its special materials and design, which provide excellent performance, especially in flexibility, wear resistance, oil resistance, and high and low temperature resistance
drag chain conveyors polyurethane cable twisted pair Parameter
YP506 HIGH FLEXIBLE DRAG CHAIN DATA PUR CABLE ( 5 million times reliability tests for drag chain)) | ||||
No. | Product Code | Cores Number and cross-sectional area | Approximate outer diameter (mm) | Outer sheath color |
(NO.Xm㎡) | ||||
1 | YP506.04.0020 | 2x2x0.2 | 5.8 | Black/ Green |
2 | YP506.04.0021 | 2x2x0.3 | 6.8 | Black/ Green |
3 | YP506.04.0022 | 2x2x0.4 | 7.8 | Black/ Green |
4 | YP506.04.0023 | 2x2x0.5 | 8.8 | Black/ Green |
drag chain conveyors polyurethane cable twisted pair Technical data
Special PUR sheath with high flexibility
●Temperature range: Mobile installation -20°C to +80°C
Fixed installation -40°C to +90°C
●Nominal voltage Uo/U 300/300V
●Test voltage 1500V
●Insulation resistance: Minimum 20 MOhm x km
●Minimum bending radius: Mobile installation 7.5x cable diameter
Fixed installation 6x cable diameter
●Complies with EU RoHS and Reach regulations requirements
drag chain conveyors polyurethane cable twisted pair Structure:
●Tinned copper (below 0.5mm²) or bare copper (0.5mm² and above) conductors Fine copper wire,
compliant with DIN VDE 0295 class 6 and IEC 60228 class 6
●Special PVC insulation
●Color-coded cores (below 0.5mm²)
●Black cores with continuous white numerical coding (0.5mm² and above)
●Optimum lay length of stranded cores
●Improved tinned copper wire braided shielding
●Minimum overall shielding coverage of 80%
●Special PVC outer sheath
●Black color (RAL 9005) with matte finish
High Flexibility 5 Million Times Drag Chain Cable Test Standards | ||
Drag Chain Bending Test Test Method: Take a 2-meter finished cable, with a bending radius of 6 times the outer diameter of the cable, a moving stroke of 900 mm, and reciprocating movement at a speed of 90 times/minute. |
Two-Wheel Winding Test Test Method: Take a 5-meter finished cable, according to the specified pulley diameter and weight of the weights. The pulley moves at a speed of 0.33 m/sec, and the moving distance is more than 1.0 meter under reciprocating conditions |
90-Degree Bend Test Test Method: Take a 2-meter finished cable, with a bending radius of 2.5 times the outer diameter of the cable, according to the standard specified weight of the weights, bending at a speed of 40 times/minute |
Judgment Criteria: 1. The number of reciprocations exceeds 5,000,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 200,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 100,000 times without open circuit or short circuit. 2. The sheath is not broken |