Oil resistant PUR cable
YP502 HIGH FLEXIBLE PUR DRAG CHAIN CONTROL SHIELD CABLE(Color Core) ( 5 million times reliability tests for drag chain)) | ||||
No. | Product Code | Cores Number and cross-sectional area | Approximate outer diameter (mm) | Outer sheath color |
(NO.Xm㎡) | ||||
1 | YP502.03.0014 | 3×0.14 | 4.2 | Black |
2 | YP502.04.0014 | .4×0.14 | 4.5 | Black |
3 | YP502.06.0014 | 6×0.14 | 5.2 | Black |
4 | YP502.08.0014 | 8×0.14 | 6 | Black |
5 | YP502.10.0014 | 10×0.14 | 6.8 | Black |
6 | YP502.12.0014 | 12×0.14 | 6.5 | Black |
7 | YP502.16.0014 | 16×0.14 | 7.2 | Black |
8 | YP502.20.0014 | 20×0.14 | 7.8 | Black |
9 | YP502.26.0014 | 26×0.14 | 9.0 | Black |
10 | YP502.02.0020 | 2×0.2 | 4.4 | Black |
11 | YP502.03.0020 | 3×0.2 | 4.6 | Black |
12 | YP502.04.0020 | 4×0.2 | 4.9 | Black |
13 | YP502.05.0020 | 5×0.2 | 5.2 | Black |
14 | YP502.06.0020 | 6×0.2 | 5.6 | Black |
15 | YP502.08.0020 | 8×0.2 | 6.5 | Black |
16 | YP502.10.0020 | 10×0.2 | 7.4 | Black |
17 | YP502.12.0020 | 12×0.2 | 7.0 | Black |
18 | YP502.16.0020 | 16×0.2 | 7.8 | Black |
19 | YP502.20.0020 | 20×0.2 | 8.5 | Black |
20 | YP502.26.0020 | 26×0.2 | 9.5 | Black |
21 | YP502.30.0020 | 30×0.2 | 9.8 | Black |
22 | YP502.02.0030 | 2×0.3 | 4.6 | Black |
23 | YP502.03.0030 | 3×0.3 | 4.8 | Black |
24 | YP502.04.0030 | 4×0.3 | 5.1 | Black |
25 | YP502.05.0030 | 5×0.3 | 5.5 | Black |
26 | YP502.06.0030 | 6×0.3 | 5.8 | Black |
27 | YP502.08.0030 | 8×0.3 | 6.8 | Black |
28 | YP502.10.0030 | 10×0.3 | 7.8 | Black |
29 | YP502.12.0030 | 12×0.3 | 7.4 | Black |
30 | YP502.16.0030 | 16×0.3 | 8.2 | Black |
31 | YP502.20.0030 | 20×0.3 | 9.0 | Black |
G= represents the yellow-green grounding wire. For more specifications or special custom products, please contact our product consultant.
Oil resistant PUR cable Technical data
●Specialized PUR sheath, highly flexible
●Tem perature range: Mobile installation: -20°C to +80°C Fixed installation: -40°C to +90°C
●Maximum overhead/sliding speed: 5 m/s, 3 m/s
●Maximum acceleration: 50 m/s
●Nominal voltage Uo/U: 300/300V
●Test voltage: 1500V
●Insulation resistance: Minimum 20 MOhmxkm
●Minimum bending radius: Mobile installation: 7.5 x cable diameter Fixed installation: 6 x cable diameter
●Complies with EU RoHS and Reach regulation
●Oil resistance: Totally oil resistant
●Flame retardancy: Compliant with IEC 60332-1-2, CEI 20-35, FT1, VW-1
Oil resistant PUR cable Structure:
●Tinned copper (below 0.5mm²) or bare copper (0.5mm² and above) conductors Fine copper wire, compliant with DIN VDE 0295 Class 6 and IEC 6 0228 Class 6
●Special PVC insulation
●Color-coded cores (below 0.5mm²)
●Black cores with continuous white numeric marking (0.5mm² and above) Yellow-green grounding wire in outer layer (3 cores and above)
●Optimal pitch twisted stranded cores
●Enhanced tinned copper wire braided shielding
●Minimum coverage 85%
●Outer sheath Low-adhesion PUR mixture, adjusted to meet the requirements of the drag chain.
●Color: gray, black,or can be color-matched according to customer requirements.
High Flexibility 5 Million Times Drag Chain Cable Test Standards | ||
Drag Chain Bending Test Test Method: Take a 2-meter finished cable, with a bending radius of 6 times the outer diameter of the cable, a moving stroke of 900 mm, and reciprocating movement at a speed of 90 times/minute. |
Two-Wheel Winding Test Test Method: Take a 5-meter finished cable, according to the specified pulley diameter and weight of the weights. The pulley moves at a speed of 0.33 m/sec, and the moving distance is more than 1.0 meter under reciprocating conditions |
90-Degree Bend Test Test Method: Take a 2-meter finished cable, with a bending radius of 2.5 times the outer diameter of the cable, according to the standard specified weight of the weights, bending at a speed of 40 times/minute |
Judgment Criteria: 1. The number of reciprocations exceeds 5,000,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 200,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 100,000 times without open circuit or short circuit. 2. The sheath is not broken |