drag chain shielded cable Parameter
| YY502 HIGH FLEXIBLE DRAG CHAIN CONTROL SHIELD CABLE(Color Core) ( 5 million times reliability tests for drag chain)) | ||||
| No. | Product Code | Cores Number and cross-sectional area | Approximate outer diameter (mm) | Outer sheath color | 
| (NO.Xm㎡) | ||||
| 1 | YY502.03.0014 | 3×0.14 | 4.2 | Black | 
| 2 | YY502.04.0014 | . 4×0.14 | 4.5 | Black | 
| 3 | YY502.06.0014 | 6×0.14 | 5.2 | Black | 
| 4 | YY502.08.0014 | 8×0.14 | 6.0 | Black | 
| 5 | YY502.10.0014 | 10×0.14 | 6.8 | Black | 
| 6 | YY502.12.0014 | 12×0.14 | 6.5 | Black | 
| 7 | YY502.16.0014 | 16×0.14 | 7.2 | Black | 
| 8 | YY502.20.0014 | 20×0.14 | 7.8 | Black | 
| 9 | YY502.26.0014 | 26×0.14 | 9.0 | Black | 
| 10 | YY502.02.0020 | 2×0.2 | 4.4 | Black | 
| 11 | YY502.03.0020 | 3×0.2 | 4.6 | Black | 
| 12 | YY502.04.0020 | 4×0.2 | 4.9 | Black | 
| 13 | YY502.05.0020 | 5×0.2 | 5.2 | Black | 
| 14 | YY502.06.0020 | 6×0.2 | 5.6 | Black | 
| 15 | YY502.08.0020 | 8×0.2 | 6.5 | Black | 
| 16 | YY502.10.0020 | 10×0.2 | 7.4 | Black | 
| 17 | YY502.12.0020 | 12×0.2 | 7.0 | Black | 
| 18 | YY502.16.0020 | 16×0.2 | 7.8 | Black | 
| 19 | YY502.20.0020 | 20×0.2 | 8.5 | Black | 
| 20 | YY502.26.0020 | 26×0.2 | 9.5 | Black | 
| 21 | YY502.30.0020 | 30×0.2 | 9.8 | Black | 
| 22 | YY502.02.0030 | 2×0.3 | 4.6 | Black | 
| 23 | YY502.03.0030 | 3×0.3 | 4.8 | Black | 
| 24 | YY502.04.0030 | 4×0.3 | 5.1 | Black | 
| 25 | YY502.05.0030 | 5×0.3 | 5.5 | Black | 
| 26 | YY502.06.0030 | 6×0.3 | 5.8 | Black | 
| 27 | YY502.08.0030 | 8×0.3 | 6.8 | Black | 
| 28 | YY502.10.0030 | 10×0.3 | 7.8 | Black | 
| 29 | YY502.12.0030 | 12×0.3 | 7.4 | Black | 
| 30 | YY502.16.0030 | 16×0.3 | 8.2 | Black | 
| 31 | YY502.20.0030 | 20×0.3 | 9.0 | Black | 
Drag chain shielded cable Technical data
Special PVC sheath with high flexibility
● Temperature range: Mobile installation: -5°C to +70°C
Fixed installation: -15°C to +80°C
● Nominal voltage Uo/U: 300/300V
● Test voltage: 1500V
● Insulation resistance: Minimum 20 MOhmxkm
● Minimum bending radius: Mobile installation: 7.5x cable diameter
Fixed installation: 6x cable diameter
● Compliant with EU RoHS and Reach regulations.
Drag chain shielded cable Structure:
Tinned copper (below 0.5mm²) or bare copper (0.5mm² and above) conductors Fine copper wire,
compliant with DIN VDE 0295 Class 6 and IEC 60228 Class 6
● Special PVC insulation
● Color-coded cores (below 0.5mm²)
● Black cores with continuous white numerical coding (0.5mm² and above), yellow-green earth wire on the outer layer (3 cores and above)
● Optimal lay length for twisted cores
● Improved tinned copper wire braided shielding
● Minimum coverage of 80%
● Special PVC outer sheath
● Black color (RAL9005), matte finish

| High Flexibility 5 Million Times Drag Chain Cable Test Standards | ||
| Drag Chain Bending Test Test Method: Take a 2-meter finished cable, with a bending radius of 6 times the outer diameter of the cable, a moving stroke of 900 mm, and reciprocating movement at a speed of 90 times/minute. | Two-Wheel Winding Test Test Method: Take a 5-meter finished cable, according to the specified pulley diameter and weight of the weights. The pulley moves at a speed of 0.33 m/sec, and the moving distance is more than 1.0 meter under reciprocating conditions | 90-Degree Bend Test Test Method: Take a 2-meter finished cable, with a bending radius of 2.5 times the outer diameter of the cable, according to the standard specified weight of the weights, bending at a speed of 40 times/minute | 
| Judgment Criteria: 1. The number of reciprocations exceeds 5,000,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 200,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 100,000 times without open circuit or short circuit. 2. The sheath is not broken | 











 
				








 







 
				
 
				
 
				
 
				
 
				
 
				
 
				