Drag Chain Power With Shielded Instrumentation Cables Parameter
YY508 HIGH FLEXIBLE DRAG CHAIN POWER CABLE With Shield( 5 million times reliability tests for drag chain)) | ||||
いいえ。 | 製品コード | コア数と断面積 | おおよその外径(mm) | 外被シース色 |
(NO.Xm㎡) | ||||
1 | YY508.02.0050 | 2×0.5 | 6.5 | Black/Orange |
2 | YY508.03.0050 | 3G0.5 | 6.8 | 黒 |
3 | YY508.04.0050 | 4G0.5 | 7.4 | Black/Orange |
4 | YY508.03.0075 | 3G0.75 | 7.2 | 黒 |
5 | YY508.04.0075 | 4G0.75 | 7.8 | Black/Orange |
6 | YY508.04.0100 | 4G1.0 | 8.4 | Black/Orange |
7 | YY508.03.0150 | 3G1.5 | 8.6 | 黒 |
8 | YY508.04.0150 | 4G1.5 | 9.4 | Black/Orange |
9 | YY508.04.0250 | 4G2.5 | 11.2 | Black/Orange |
The MOQ for the above cable is one roll (100 M). If the cable with PUR sheath, the MOQ is 400 meters.
Drag Chain Power With Shielded Instrumentation Cables Technical data
● Special PVC sheath, highly flexible
●Temperature range: Mobile installation: -5°C to +70°C
Fixed installation: -15°C to +80°C
● Nominal voltage Uo/U: 300/500V
●Test voltage: 2000V
●Insulation resistance: Minimum 20 MOhmxkm
● Minimum bending radius: Mobile installation: 7.5 x cable diameter
Fixed installation: 6 x cable diameter
●Complies with EU RoHS and Reach regulations.
Drag Chain Power With Shielded Instrumentation Cables Structure:
● Bare copper conductor, fine copper wire Complies with DIN VDE 0295 class 6 and IEC 60228 class 6
● Special PVC insulation
● Color-coded core identification
● Optimal lay-up of stranded cores
● Yellow-green grounding wire (for 3 cores and above)
● Improved tinned copper wire braided shielding
● Minimum coverage rate of 80%
● Special PVC outer sheath
● Black color (RAL9005), matte finish.
High Flexibility 5 Million Times Drag Chain Cable Test Standards | ||
Drag Chain Bending Test Test Method: Take a 2-meter finished cable, with a bending radius of 6 times the outer diameter of the cable, a moving stroke of 900 mm, and reciprocating movement at a speed of 90 times/minute. |
Two-Wheel Winding Test Test Method: Take a 5-meter finished cable, according to the specified pulley diameter and weight of the weights. The pulley moves at a speed of 0.33 m/sec, and the moving distance is more than 1.0 meter under reciprocating conditions |
90-Degree Bend Test Test Method: Take a 2-meter finished cable, with a bending radius of 2.5 times the outer diameter of the cable, according to the standard specified weight of the weights, bending at a speed of 40 times/minute |
Judgment Criteria: 1. The number of reciprocations exceeds 5,000,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 200,000 times without open circuit or short circuit. 2. The sheath is not broken | Judgment Criteria: 1. The number of reciprocations exceeds 100,000 times without open circuit or short circuit. 2. The sheath is not broken |