This type of robot cable is particularly suitable for SCARA robots and other machinery operating in complex environments where long-term twisting, bending, and high-strength applications are required. It can withstand continuous and high-intensity mechanical stress from bending and twisting, making it an excellent choice to ensure the reliability and extended lifespan of robotic products.
Thông số kỹ thuật
● Special fluororesin insulation, special PVC sheath with ultra-high strength and flexibility.
● Complies with TUV 2 PfG 2577 Class V requirements.
● Temperature range: For mobile installation: -20°C to +80°C For fixed installation: -40°C to +105°C
● Nominal voltage Uo/U:Power supply: 300/500V Data: 300/300V
● Test voltage: Power supply: 2000V Data: 1500V
● Insulation resistance: Minimum 100 MOhmxkm
● Minimum bending radius: For mobile installation: 6 times the cable diameter For fixed installation: 4 times the cable diameter
● Complies with EU RoHS and REACH regulations.
Kết cấu
● Tin-plated copper (below 0.5mm2) or bare copper (0.5mm2 and above) conductors, ultra-fine copper wire, compliant with DIN VDE 0295 Class 6 and IEC 60228 Class 6.
● Special fluororesin insulation.
● Color-coded core wires.
● Optimal pitch twisting of the cores.
● Improved tinned copper wire braided shielding.
● Minimum coverage rate of 85%.
● Vỏ ngoài bằng nhựa PVC đặc biệt.
● Black color (RAL9005) with a matte finish.
INDUSTRIAL ROBOT DRAG CHAIN CABLE ( 50 million times reliability tests for drag chain) | ||||
KHÔNG. | Mã sản phẩm | Số lõi và diện tích mặt cắt ngang | Đường kính ngoài gần đúng (mm) | Màu vỏ ngoài |
(SỐ.Xm㎡) | ||||
1 | RO-FY2001.56.2417 | 3X(4x2x0.2)+(7x2x0.2+3x(6×1.0)+2xtube | 24.5 | Đen |
Có sẵn tùy chỉnh các mô hình đặc biệt theo yêu cầu, bao gồm cáp có diện tích mặt cắt dây dẫn khác nhau, vật liệu, tấm chắn, màu sắc và các thông số kỹ thuật khác cho vỏ bọc.
Robot body cable testing standards
1.Vertical torsion test
Test method: Take a 2-meter finished cable, fix the distance at 200mm, rotate the angle at positive and negative 180 degrees, and perform torsion at a speed of 12 times per minute for 1 minute each time.
Judgment criteria: 1.No open circuit or short circuit after exceeding 500,000 cycles of back and forth movement. 2.No cracking in the sheath.
2.2D torsion test
Test method: Take a 2.5-meter finished cable, fix the distance at 1 meter, apply the standard specified weight, rotate the angle at positive and negative 90 degrees or 180 degrees, and perform torsion at a speed of 60 cycles per minute.
Judgment criteria: 1.No open circuit or short circuit after exceeding 5,000,000 cycles of back and forth movement. 2.No cracking in the sheath.
3.3D torsion test
Test method: Take a 1-meter finished cable, fix the distance according to the standard requirements. The upper part is bent at positive and negative 90 degrees, while the base rotates at positive and negative 180 degrees. Perform bending and torsion at a speed of 30 cycles per minute
Judgment criteria: 1.No open circuit or short circuit after exceeding 5,000,000 cycles of back and forth movement. 2.No cracking in the sheath.
4.Two-wheel bending test
Test method: Take a 5-meter finished cable and, according to the specified pulley diameter and weight, move the pulley back and forth at a speed of 0.33 meters per second with a travel distance of at least 1.0 meter. Judgment criteria:
Judgment criteria: 1.No open circuit or short circuit after exceeding 1,000,000 cycles of back and forth movement. 2.No cracking in the sheath.
5.90-degree bend test
Test method: Take a 2-meter finished cable, with a bending radius of 2.5 times the cable diameter, apply the weight specified by the standard, and perform bending at a speed of 40 cycles per minute.
Judgment criteria: 1.No open circuit or short circuit after exceeding 1,000,000 cycles of back and forth movement. 2.No cracking in the sheath.
6.Bending and rotating test
Test method: Take a 1.5-meter finished cable, fix the distance at 300mm, with a bending radius of 150mm, and rotate at a speed of 50 revolutions per minute.