This cable is suitable for high-frequency current used in wire cutting. The cable must meet high requirements for mechanical, chemical, and thermal performance while also being able to withstand high temperatures, metal chip splashing, oil resistance, and other chemicals.
المقياس التقني
● Special PVC insulation, special PVC or PUR sheath with high strength and bending/torsion performance.
● Temperature range:
Fixed installation temperature range: PVC: -10°C to +80°C
Cold-resistant and heat-resistant PVC: -40°C to +105°C Oil-resistant
PUR: -40°C to +105°C
Mobile installation temperature range: PVC: -5°C to +80°C
Cold-resistant and heat-resistant PVC: -15°C to +105°C
Oil-resistant PUR: -20°C to +105°C
● Nominal voltage: 30V.
● Test voltage: 500V.
● Insulation resistance: minimum 100 MOhm xkm.
● Minimum bending radius: Mobile installation: 7.5 times the cable diameter. Fixed installation: 6 times the cable diameter.
● Compliance with EU RoHS and Reach regulations.
Cable Structure
● Tinned copper conductor, ultra-fine copper wire Complies with DIN VDE 0295 Class 6 and IEC 60228 Class 6
● Special fluororesin insulation
● Core wires are color-coded
● Core wires are twisted with optimal lay length
● Improved tinned copper wire shielding
● Minimum coverage of 90%
● لون أسود (RAL9005)، لمسة نهائية غير لامعة
HIGH FREQUENCY CURRENT CABLE FOR WIRE CUTTING
(5 مليون مرة اختبارات الموثوقية لسلسلة السحب) |
||||
لا. | كود المنتج | عدد النوى ومنطقة المقطع العرضي | القطر الخارجي التقريبي (مم) | لون الغلاف الخارجي |
(NO.Xm㎡) | ||||
1 | L-YY508.01.0577 | 5.77 | 8 | أسود |
2 | L-YP508.01.0225 | 2.25 | 6.2 | أسود |